UMG 512-PRO
Janitza UMG 512-PRO Left 1 S
Janitza UMG 512-PRO Front 1 S
Janitza UMG 512-PRO Right 1 S
Janitza UMG 512-PRO Back S

The Janitza UMG 512-PRO is suitable for monitoring power quality according to common standards, e.g. EN 50160, IEEE519 or EN 61000-2-4.

Contact us
Icon Product-Communication

Communication

Export of power quality data via COMTRADE format

Icon Certified

Certification

Testing and certification by external testing laboratory

Icon Voltage-Quality

Power Quality

Power quality analyzer according to IEC 61000-4-30 Class A

The UMG 512-PRO (Class A) power quality analyzer measures all power quality parameters (e.g. harmonics currents up to the 63rd, flicker, short-term interruptions, etc.) and additionally serves as a residual current monitoring device. In contrast to the UMG 511, it has a thermistor input. The device is based on the current standards, e.g. EN 50160, IEEE519 or EN 61000-2-4. Each UMG 512-PRO has two digital inputs and two digital outputs.

Main features of the UMG 512-PRO

Class A

Class A measurement devices are certified in accordance with IEC 61000-4-30. This standards provides detailed specifications that a network analyzer must meet so that the results can also be used in cases of dispute. The standard defines the necessary parameters, suitable measurement methods, accuracy, and bandwidths. Consequently, results can be easily reproduced and compared.

Power quality

Reliable operation of modern plants and systems always requires high supply reliability and good power quality.

UMG measurement devices reliably record, analyze, and document all disturbance variables such as harmonics current, unbalances, transients, voltage dips, overvoltages, flicker, phase shifts, and reactive power.

BACnet

BACnet is one of the most important communication standards for building services engineering, primarily because of its compatibility with a wide variety of hardware and uniform, cross-vendor communication.

As soon as a UMG measurement device has received its BACnet ID and is integrated into the network, it is recognized by the system and displayed in the browser. This makes configuration very easy.

Device homepage

The web server on the measurement device provides a wide range of data in a clearly structured format. Users do not need to install any software on their PC, a standard web browser is sufficient. Users enter the IP address of the measurement device in the URL window of the browser and the homepage of the measurement device appears on the screen. In addition to the modern homepage, apps are also available for an extended range of functions.

Residual current monitoring (RCM)

Powerful residual current monitoring (RCM) detects residual currents at the initial stage, before they lead to system failures or even fires. It is already integrated into certain UMG measurement devices. The required RCM measuring current transformers can even be retrofitted if required. Continuous RCM monitoring significantly increases system safety and availability. In certain applications such as data centers, residual current monitoring is mandatory due to high availability requirements.

Residual current monitoring (RCM)

Modbus RTU devices that are connected to the master device as slaves can be very easily integrated into an Ethernet architecture via the Ethernet Modbus gateway. For devices with an identical file format and matching function codes, this is possible directly via the Modbus RTU interface.

Apps included

App-Messwertmonitor

Measured value monitor

Graphically prepared displays on the device's own homepage with no additional software installation.

App-EN-Watchdog

EN 50160 Watchdog PRO

Continuous monitoring of power quality according to EN 50160 in energy supply networks.

App-IEC-Watchdog

IEC 61000-2-4 Watchdog PRO

Continuous monitoring of the power quality according to IEC 61000-2-4 in customer-side power grids.

Your benefits

  • Functional expansion of Janitza measurement devices through in-house apps
  • Easy interpretation and analysis of measurement data, e.g. through the integrated traffic light principle for PQ status
  • Display of available apps and their functions via app management
  • Redundancy – 100% security of the measurement data in the device memory
  • Most important information at a glance via QR code

Get in touch

Get personal advice now

Your request is important to us and we guarantee fast and professional processing.